Mainframe |
Synergy |
Sentinel |
meDAQ |
Win600e |
REVelation |
| |
 |
 |
 |
 |
 |
| Summary Description |
Portable Dynamic DAQ |
Rugged Wireless Distributed DAQ |
Compact Portable Transient Recorder |
High Channel Count Mainframe |
Specialty DAQ for Engine Analysis |
| Analog Bandwidth |
1 MHz |
20 kHz |
to 20 MHz |
to 20 MHz |
to 20 MHz |
Digitizer
(per channel) |
2 MS/s
16 bit |
50 kS/s
16 bit |
bit to
50 MS/s |
bit to
50 MS/s |
bit to
50 MS/s |
| Stream rate (per channel) |
200 kS/s |
to 50 kS/s |
option, to
50 kS/s |
option, to
50 kS/s |
none |
| Max Aggregate Sample Rate |
unlimited |
1 MS/s |
unlimited |
unlimited |
- |
| Signal Conditioning |
Universal voltage, bridge, ICP-type, TC on all
channels |
Configured per channel on module. Voltage, bridge,
ICP-type, TC, RTD |
Digitizer card option. Voltage, bridge, ICP-type |
Digitizer card option. Voltage, bridge, ICP-type |
Digitizer card option. Voltage, bridge, ICP-type |
| Anti-alias Filtering |
Selectable time and freq domain, 10 pole analog
+ digital FIR, IIR |
Digital FIR, automatic |
Optional 8 pole Butterworth or Bessel analog,
256 frequency selections |
Optional 8 pole Butterworth or Bessel analog,
256 frequency selections |
Optional 8 pole Butterworth or Bessel analog,
256 frequency selections |
| High-speed channels per chassis |
8 - 16 |
4 - 8 per module |
2 -16 |
2 - 64 |
2 - 64 |
| Expandable to # of channels |
512 |
unlimited |
128 |
512 |
64 |
| Low-speed thermocouple inputs |
option, 8 via USB |
no |
no |
option, 8-16 via PCI |
option, 8-16 via PCI |
| Digital Inputs |
Up to 16 ch from J1850-PWM, J1850-VPW,
CAN, KW2000, ISO-9141 vehicle buses |
| Ethernet Interface |
2 x 1GB built-in switch ports |
10 Mb/s wired, 802.11 b/g wireless |
100 Mb |
100 Mb |
100 Mb |
| Control PC |
Internal or External |
External |
External |
Built-in or external |
Built-in or external |